therapeutic
& cosmedical
light technology

About Polilight® PDT
The Polilight®1 PDT is designed to be a multipurpose 500Watt medical light source with selectable optical output bands. It is designed to be compact, portable and self calibrating; to be used in a number of medical light based treatments or examination applications and have a multiplicity of functions for typically a dermatologist and/or cosmetic surgeon.
The Polilight® PDT‘s primarily application to date to be used in Photo Dynamic Therapy (PDT) applications in either device-drug combination or other purely light based therapies. To date the Polilight® PDT has been successfully used in clinical trials for the treatment of Basal Cell Carcinoma (BCC), Bowen Disease (BD) and Actinic Keratosis (AK). In these applications the Polilight® PDT is used to activate a photosensitive drug.
1 ® - “Polilight” is registered Class10 Medical and Surgical Trade Mark (Madrid convention, EU, USA, Australia).
Polilight® PDT Configurations
The Polilight® PDT is design to include up to 12 optical output bands. The optical bands can be from the Ulta-violet (UVA), bands within the visible spectrum (400-700nm range) and Infra-Red bands (700-1000nm). The Polilight® PDT configuration used within the clinical trial for BBC, BD, and AK ( see above) included a UVA 320 - 380nm, 415nm band +/- 20nm and a broad band 575 - 655 (80nm bandpass).
Polilight® PDT POL.1001 Three band configuration – technical specification
Model |
POL.1001 3B |
||
| Application | Selection of applications from treatment database within remote control. |
||
| Polilight PDT Lamp unit | Characteristics |
||
Operation - Remote Control ![]() |
6 button remote with visual display unit, 2 meter cable, Operator Functions: Automated Background Functions: Physical Characteristics |
||
Optical Power Meter![]() |
Integrated optical power meter, 2 meter cable Function Features Physical Characteristics |
||
| Optical Output Bands | Band 1 |
Band 2 |
Band 3 |
| Band Type (function) | Diagnostic (Ultra-violet UVA) |
Diagnostic(Purple) |
Treatment (Orange-Red) |
| Total Optical Output Power | 2.7 Watt Optical |
1.0 Watt Optical |
5.7 Watt Optical |
| Maximum Output Intensity (5cm distance) | 750mW/cm2 |
170mW/cm2 |
1.5W/cm2 |
| Optical Output Band Central Wavelength | 350 +/- 5nm |
415 +/- 5nm |
612.5 +/- 5nm |
| Bandwidth | 80 +/- 2nm |
40 +/- 2nm |
85 +/- 2nm |
| Standard Dose | Not applicable Note: light used only for diagnostic purposes at defaulted low power setting |
Not applicable Note: light used only for diagnostic purposes at defaulted low power setting. |
37J/cm2 (Note: Other applications can define a specific standard dose for each application) |
| Treatment Time (for standard dose) | Not applicable |
Not applicable |
10 seconds to 40 minutes Calculated automatically from power meter |
Specifications are subject to change.